Main SP Tables-1
D146/D147/D148/D149/D150 2-38 System Maintenance Section
Paper through target temperature: middle thick paper: BW: center: low speed
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
112
M-thick:BW:Press:Low Speed *ENG [0 to 200 / 118 / 1deg/step]
Do not change. paper through target temperature: middle thick paper: BW:
pressure: low speed
113
Thick1:FC:Center:Low Speed *ENG [100 to 180 / 128 / 1deg/step]
Paper through target temperature: Thick paper 1: FC: center: low speed
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
114
Thick1:FC:Press:Low Speed *ENG [0 to 200 / 118 / 1deg/step]
Do not change. paper through target temperature: Thick paper 1: FC: pressure:
low speed
115
Thick1:BW:Center:Low Speed *ENG [100 to 180 / 127 / 1deg/step]
Paper through target temperature: Thick paper 1: BW: center: low speed
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
116
Thick1:BW:Press:Low Speed *ENG [0 to 200 / 118 / 1deg/step]
Do not change. paper through target temperature: Thick paper 1: BW: pressure:
low speed
117
Special1:FC:Center:Low Spee
*ENG [100 to 180 / 137 / 1deg/step]
paper through target temperature: Thick paper 1: BW: center: low speed
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
118
Special1:FC:Press:Low
Speed
*ENG [0 to 200 / 118 / 1deg/step]