6011
[1-Pass ADF INPUT Check]
See page 671
6012
[1-Pass ADF OUTPUT Check]
See page 741
6016
[Original Size Detect Setting]
Sets which original size is to be determined in regard to the two original sizes which are
impossible to be determined in ADF. Size for each bit differs depending on destinations.
Sets the bit for default size for "0" when taking priority, and sets for "1" when Switch Size
determines.
001 - *ENG [0 to 255 / 0 / 1/step]
6017
[DF Magnification Adj.]
Executes Magnification fine adjustment. Changes Line Speed along with the Magnification
Setting value.
001 - *ENG [-5.0 to 5.0 / 0.0 / 0.1 %/step]
6020
[Skew Correction Moving Setting]
Skew Correction Moving (Skew Correction 2) into Interval Sensor Roller in ADF is executed
only for small sizes (B6, A5, HLT) by default. It is possible to set to execute Skew Correction
Moving for all sizes by setting for "1".
001 - *ENG [0 or 1 / 0 / 1/step]
6030 [DF Hinge] (SSP)
001
Hinge Open Counter ENG [0 to 999999 / 0 / 1/step]
Records number of times that hinge opened with ADF lift up.
002
Hinge Open Counter State ENG [0 or 1 / 0 / 1/step]
Records status of open and close DF hinge when main unit is turned OFF.
SP6-XXX (Peripherals)
363