004
Latest:L:RO ENG [0 to 16383 / 0 / 1digit/step]
Displays Black level digital adjustment value (L side/RED/ODD Pixel).
Black level adjustment is continuously done hardwarelly by SBUs ASIC (SCAT).
Black level is checked when Scanner turns on, then Adjustment value is given.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
4655 [Black Level Adj Value(Digital)]
001
Latest:F:GE ENG [0 to 16383 / 0 / 1digit/step]
Displays Black level digital adjustment value (F side/GREEN/EVEN Pixel).
Black level adjustment is continuously done hardwarelly by SBUs ASIC (SCAT).
Black level is checked when Scanner turns on, then Adjustment value is given.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
002
Latest:F:GO ENG [0 to 16383 / 0 / 1digit/step]
Displays Black level digital adjustment value (F side/GREEN/ODD Pixel).
Black level adjustment is continuously done hardwarelly by SBUs ASIC (SCAT).
Black level is checked when Scanner turns on, then Adjustment value is given.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
003
Latest:L:GE ENG [0 to 16383 / 0 / 1digit/step]
Displays Black level digital adjustment value (L side/GREEN/EVEN Pixel).
Black level adjustment is continuously done hardwarelly by SBUs ASIC (SCAT).
Black level is checked when Scanner turns on, then Adjustment value is given.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
004
Latest:L:GO ENG [0 to 16383 / 0 / 1digit/step]
Displays Black level digital adjustment value (L side/GREEN/ODD Pixel).
Black level adjustment is continuously done hardwarelly by SBUs ASIC (SCAT).
Black level is checked when Scanner turns on, then Adjustment value is given.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
4656 [Black Level Adj Value(Digital)]
2. Main SP Tables-4