001
Latest:F:BE ENG [0 to 16383 / 0 / 1digit/step]
Displays Black level digital adjustment value (F side/BLUE/EVEN Pixel).
Black level adjustment is continuously done hardwarelly by SBUs ASIC (SCAT).
Black level is checked when Scanner turns on, then Adjustment value is given.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
002
Latest:F:BO ENG [0 to 16383 / 0 / 1digit/step]
Displays Black level digital adjustment value (F side/BLUE/ODD Pixel).
Black level adjustment is continuously done hardwarelly by SBUs ASIC (SCAT).
Black level is checked when Scanner turns on, then Adjustment value is given.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
003
Latest:L:BE ENG [0 to 16383 / 0 / 1digit/step]
Displays Black level digital adjustment value (L side/BLUE/EVEN Pixel).
Black level adjustment is continuously done hardwarelly by SBUs ASIC (SCAT).
Black level is checked when Scanner turns on, then Adjustment value is given.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
004
Latest:L:BO ENG [0 to 16383 / 0 / 1digit/step]
Displays Black level digital adjustment value (L side/BLUE/ODD Pixel).
Black level adjustment is continuously done hardwarelly by SBUs ASIC (SCAT).
Black level is checked when Scanner turns on, then Adjustment value is given.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
4658 [Analog Gain Adjust]
001
Latest:F:R *ENG [0 to 14 / 0 / 1digit/step]
Displays Analog gain adjustment value (F side/RED Pixel).
White level adjustment will be done to keep hold of image signal’s dynamic range when
Scanner turns on.
Gain adjustment will be done hardwarelly by SBUs ASIC (SCAT) and be given, cause to
the fact that White level adjustment will amplify or attenuated image signal.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
SP4-XXX (Scanner)
143