004
Latest:L:BO *ENG [0 to 1023 / 0 / 1digit/step]
Displays Digital gain adjustment value (L side/BLUE/ODD Pixel).
White level adjustment will be done to keep hold of image signal’s dynamic range when
Scanner turns on.
Gain adjustment will be done hardwarelly by SBUs ASIC (SCAT) and be given, cause to
the fact that White level adjustment will Amplify or Attenuated image signal.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
4670 [Black Level Adj Value(Analog)]
001
Factory Set:F:RE *ENG [0 to 127 / 0 / 1digit/step]
Display/Saves Factory Black level analog adjusting value (F side/RED/EVEN Pixel)
Factory Black level analog adjusting value from Main unit warranty process is saved.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
002
Factory Set:F:RO *ENG [0 to 127 / 0 / 1digit/step]
Display/Saves Factory Black level analog adjusting value (F side/RED/ODD Pixel)
Factory Black level analog adjusting value from Main unit warranty process is saved.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
003
Factory Set:L:RE *ENG [0 to 127 / 0 / 1digit/step]
Display/Saves Factory Black level analog adjusting value (L side/RED/EVEN Pixel)
Factory Black level analog adjusting value from Main unit warranty process is saved.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
004
Factory Set:L:RO *ENG [0 to 127 / 0 / 1digit/step]
Display/Saves Factory Black level analog adjusting value (L side/RED/ODD Pixel)
Factory Black level analog adjusting value from Main unit warranty process is saved.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
4671 [Black Level Adj Value(Analog)