001
Factory :F:B *ENG [0 to 14 / 0 / 1digit/step]
Display/Saves Factory Analog gain adjusting value (F side/BLUE Pixel)
Factory Analog gain adjusting value from Main unit warranty process is saved.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
002
Factory :L:B *ENG [0 to 14 / 0 / 1digit/step]
Display/Saves Factory Analog gain adjusting value (L side/BLUE Pixel)
Factory Analog gain adjusting value from Main unit warranty process is saved.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
4680 [Digital Gain Adjust]
001
Factory :F:RE *ENG [0 to 1023 / 0 / 1digit/step]
Display/Saves Factory Digital gain adjusting value (F side/RED/EVEN Pixel)
Factory Digital gain adjusting value from Main unit warranty process is saved.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
002
Factory :F:RO *ENG [0 to 1023 / 0 / 1digit/step]
Display/Saves Factory Digital gain adjusting value (F side/RED/ODD Pixel)
Factory Digital gain adjusting value from Main unit warranty process is saved.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
003
Factory :L:RE *ENG [0 to 1023 / 0 / 1digit/step]
Display/Saves Factory Digital gain adjusting value (L side/RED/EVEN Pixel)
Factory Digital gain adjusting value from Main unit warranty process is saved.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
004
Factory :L:RO *ENG [0 to 1023 / 0 / 1digit/step]
Display/Saves Factory Digital gain adjusting value (L side/RED/ODD Pixel)
Factory Digital gain adjusting value from Main unit warranty process is saved.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
4681 [Digital Gain Adjust]
SP4-XXX (Scanner)
153