001
Factory Setting *ENG [0 to 255 / 0 / 1digit/step]
Display/Saves Factory White level; peak data (GREEN) for CIS.
Factory white level; peak data from Main unit warranty process is saved.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC)
4789 CIS White Level Peak Data: B
001
Factory Setting *ENG [0 to 255 / 0 / 1digit/step]
Display/Saves Factory White level; peak data (BLUE) for CIS.
Factory white level; peak data from Main unit warranty process is saved.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC)
4790 [CIS White Level Peak Data: R]
001
- ENG [0 to 255 / 0 / 1digit/step]
Displays White level; peak data (RED) for CIS.
Checks White level by scanning White basis roller witch is set to mach CIS DF powers ON.
Reading level of White basis roller from white level check is given.
When white level peak scanning value is abnormal, SC188-00 (White level error) is given.
Cause of error is shown in SP4-475-001.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
4791 [CIS White Level Peak Data: G]
001
- ENG [0 to 255 / 0 / 1digit/step]
Displays White level; peak data (GREEN) for CIS.
Checks White level by scanning White basis roller witch is set to mach CIS DF powers ON.
Reading level of White basis roller from white level check is given.
When white level peak scanning value is abnormal, SC188-00 (White level error) is given.
Cause of error is shown in SP4-475-001.
Use for design evaluation, analyzing cause of malfunction (abnormal images, SC).
4792 [CIS White Level Peak Data: B]
2. Main SP Tables-4
170