5185
[TCRU: Set Machine]
• TCRU: Set Machine
•
TCRU becomes intended when “On” is selected and Replacement Banner Display etc.
switch.
001 - *ENG
[0 or 1 / 0 / 1/step]
0:OFF
1:ON
5186
[RK4]
Enables or disables the prevention for RK4 (accounting device) disconnection.
If the RK4 is disconnected for 10 seconds when this SP is set to "1 (Enable)", the machine
automatically jams a sheet of paper.
001 - *ENG
[0 or 1 / 0 / 1/step]
0: Disable
1: Enable
5188
[Copy Nv Version]
Displays the version number of the NVRAM on the controller board.
001 - *CTL [- / - / - ]
5191
[Mode Set]
Shifts to the power save mode or not.
001 Power Str Set *CTL
[0 or 1 / 1 / 1/step]
0: OFF
1: ON
5193
[External Controller Info. Settings]
External controler settings.
3. Main SP Tables-5
226