003
Cancellation On/Off *CTL
[0 or 1 / 0 / 1/step]
0: OFF (lockout not cancelled)
1: ON (system waits, cancels lockout if
correct user ID and password are
entered)
Determines whether the system waits the prescribed time for input of a correct user ID and
password after an account lockout has occurred.
004
Cancelation Time *CTL [1 to 9999 / 60 / 1min./step]
Determines the length of time that the system waits for correct input of the user ID and
password after a lockout has occurred. This setting is used only if
SP5413-3 is set to "1" (on).
5414 [Access Mitigation]
001
Mitigation On/Off *CTL
[0 or 1 / 0 / 1/step]
0: OFF, 1: ON
Switches on/off masking of continuously used IDs and passwords that are identical.
002
Mitigation Time *CTL [0 to 60 / 15 / 1min./step]
Sets the length of time for excluding continuous access for identical user IDs and
passwords.
5415 [Password Attack]
001
Permissible Number *CTL [0 to 100 / 30 / 1 time/step]
Sets the threshold number of attempts to attack the system with random passwords to gain
illegal access to the system.
002
Detect Time *CTL [1 to 10 / 5 / 1sec/step]
Sets a detection time to count a password attack.
5416 [Access Information]
001
Access User Max Num *CTL [50 to 200 / 200 / 1 users/step]
Limits the number of users used by the access exclusion and password attack detection
functions.
3. Main SP Tables-5