001
System Log Disp *CTL
[0 or 1 / 0 / 1/step]
0: Display OFF
1: Display ON
Determines whether an error code appears in the system log after a user authentication
failure occurs.
002
Panel Disp *CTL
[0 or 1 / 1 / 1/step]
0: Display OFF
1: Display ON
Determines whether an error code appears on the operation panel after a user
authentication failure occurs.
5490
[MF KeyCard]
Sets up operation of the machine with a keycard.
001 Job Permit Setting *CTL
[0 or 1 / 0 / 1/step]
0: Disabled. Cancels operation
without a user code.
1: Enabled. Allows operation without
a user code.
002 Count Mode Setting *CTL [- / - / -]
5491 [Optional Counter]
001 Detail Option *CTL
[ - / 0x00 / 0x01/step]
bit0: Forced Job Canceling
-1:Yes, 2: No
5501 [PM Alarm]
001 PM Alarm Level *CTL
[0 to 9999 / 0 / 1/step]
0: Alarm off
1 to 9999: Alarm goes off when Value
(1 to 9999) x 1000 > PM counter
5504 [Jam Alarm]
3. Main SP Tables-5