001
- *CTL
[0 to 3 / 3 / 1/step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
Sets the alarm to sound for the specified jam level (document miss feeds are not included).
5505
[Error Alarm]
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the error alarm
counter decreases by "1" when an SC is not detected during a set number of copied sheets
(for example, default 700 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
001 Error Alarm *CTL
[0 to 255 / 19 / 1hundred/step]
0: Alarm Off
5507
[Supply/CC Alarm]
Enables or disables the sending of supply calls via @Remote.
001 Paper Supply Alarm *CTL
[0 or 1 / 0 / 1/step]
0: OFF
1: ON
002 Staple Supply Alarm *CTL
[0 or 1 / 1 / 1/step]
0: OFF
1: ON
003
Toner Supply Alarm *CTL
[0 or 1 / 1 / 1/step]
0: OFF
1: ON
If you select "1" the alarm will sound when the copier detects toner end.