003
Continuous Door Open *CTL
[0 or 1 / 1 / 1/step]
0: Disable, 1: Enable
Enables/disables initiating a call when the front door remains open.
011
Jam Detection: Time Length *CTL [3 to 30 / 10 / 1min./step]
Sets the time a jam must remain before it becomes an “unattended paper jam”. This setting
is enabled only when SP5508-004 is set to "1".
012
Jam Detection: Continuous Count *CTL [2 to 10 / 5 / 1time/step]
Sets the number of consecutive paper jams required to initiate a call. This setting is enabled
only when SP5508-004 is set to "1".
013
Door Open: Time Length *CTL [3 to 30 / 10 / 1min./step]
Sets the length of time the door remains open before the machine initiates a call. This
setting is enabled only when SP5-508-004 is set to "1".
5513 [PartsAlermlevelCount]
001
Normal *CTL [1 to 9999 / 300 / 1 K]
Call in at the point that the counter of “PM Parts Counter Display: Normal (SP7-617-001)”
reaches this level (K).
002
Df *CTL [1 to 9999 / 300 / 1 K]
Call in at the point that the counter of “PM Parts Counter Display: Df (SP7-617-002)”
reaches this level (K).
5514 [PartsAlermlev]
001 Nomal *CTL [0 or 1 / 1/ 1 /step]
002
Df *CTL [0 or 1 / 0/ 1 /step]
Sets ON/OFF (Call in or not) of DF paper feed guide.
5515
[SC/Alarm Setting]
With @Remote in use, these SP codes can be set to issue an SC call when an SC error
occurs. If this SP is switched off, the SC call is not issued when an SC error occurs.
SP5-009 to 721 (Mode)
245