001 SC Call *CTL
[0 or 1 / 1 / 1/step]
0: OFF
1: ON
002 Service Parts Near End Call *CTL
003 Service Parts End Call *CTL
004 User Call *CTL
006 Communication Test Call *CTL
007 Machine Information Notice *CTL
008 Alarm Notice *CTL
009 Non Genuine Tonner Ararm *CTL
010 Supply Automatic Ordering Call *CTL
011 Supply Management Report Call *CTL
012 Jam/Door Open Call *CTL
5516
[Individual PM Part Alarm Call]
With @Remote in use, these SP codes can be set to issue a PM alarm call when one of SP
parts reaches its yield.
001
Disable/Enable Setting (0:Not
Send,1:Send)
*CTL
[0 or 1 / 1 / - ]
0: Not send
1: Send
004 Percent yield for triggering PM alert *CTL [1 to 255 / 75 / 1 %/step]
5517 [-]
001
- *CTL [0 or 1 / 0/ 1 /step]
Calls in each time sheets are printed the amout total counter (SP8-581-001) provides.
Pages to call in can be set with SP5-517-002: Malfunction predicting alarm: Calling in
sheets interval.
002
- *CTL [10 to 255 / 10/ 1 /step]
Sets interval of pages to call in for Malfunction predicting alarm.
Calls in when total counter reaches multiple sheets of (this SP’s value *100)
3. Main SP Tables-5