3323
[Vsg Adj OK?]
Displays Vsg Adjustment Execution Result. (SP is assigned to be compatible with common
model series)
•
Left digit: TM/P sensor (R)
• Right digit: TM/P sensor (L)
Displays result by each sensor from left in R, then L order.
Code Result detail
0 Did not EXEC. (SP default)
1 Succeed -
2 ID sensor proofread error
Out of range from Vsg= Vsg_reg(target value)
±x.x[V/step]
3 Offset voltage error Voffset_reg>Max. or Voffset_dif>Max.
4 LED Ampere Max. error. Ifsg>Max.
5 ID sensor output error. Vsg< Vsg_reg(error)
9 Kill Kill by error of door open, power off.
001 History:Latest *ENG [0 to 999 / 0 / 1/step]
002 History:Latest2 *ENG [0 to 999 / 0 / 1/step]
003 History:Latest3 *ENG [0 to 999 / 0 / 1/step]
004 History:Latest4 *ENG [0 to 999 / 0 / 1/step]
005 History:Latest5 *ENG [0 to 999 / 0 / 1/step]
006 History:Latest6 *ENG [0 to 999 / 0 / 1/step]
007 History:Latest7 *ENG [0 to 999 / 0 / 1/step]
008 History:Latest8 *ENG [0 to 999 / 0 / 1/step]
009 History:Latest9 *ENG [0 to 999 / 0 / 1/step]
010 History:Latest10 *ENG [0 to 999 / 0 / 1/step]
3330 [ID.Sens Coef :Disp]
1. Main SP Tables-3