001
K2(Latest) *ENG
[0.0000 to 5.0000 / 0.3240 /
0.0001/step]
Displays the latest value of Sensitivity Correction Coefficient: K2 of ID sensor.
011
K5(Latest) *ENG
[0.0000 to 5.0000 / 2.5600 /
0.0001/step]
Displays the latest value of Sensitivity Correction Coefficient: K5 of ID sensor.
3331
[ID.Sens Coef :Set]
Shipping inspection value of ID/TM Sensor indicated on the bar code.
021 K2: Check *ENG
[0.000 to 1.000 / 0.500 / 0.001/
step]
031 Diffuse Corr *ENG [0.75 to 1.35 / 1.00 / 0.01/step]
041 Vct_reg_slope Check *ENG
[0.0000 to 1.0000 / 0.0000 / 0.0001
V/mA]
046 Vct_reg_Xint Check *ENG [0.0 to 25.5 / 0.0 / 0.1mA]
051 Vct_dif_slope Check *ENG
[0.0000 to 1.0000 / 0.0000 / 0.0001
V/mA]
056 Vct_dif_Xint Check *ENG [0.0 to 25.5 / 0.0 / 0.1mA]
3400
[Toner Supply Type]
Selects Toner Supply Type
001 K ENG
[0 to 4 / 4 / 1/step]
0: Fixed Supply
4: DANC
002 C ENG
003 M ENG
004 Y ENG
3440
[Fixed Supply Mode]
Sets Toner Supply Rate for Fixed Supply Mode.
SP3-XXX (Process)