002
Rel Humidity *ENG [0 to 100 / 0 / 0.1%RH/step]
Displays Drum Stop Environment (Relative Humidity).
003
Abs Humidity *ENG [0 to 99 / 0 / 0.1g/m3/step]
Displays Drum Stop Environment (Absolute Humidity).
3529 [ProCon Interval Control :Set]
001
Gamma Corr *ENG [0 to 1 / 1 / 1/step]
Sets ON/OFF for Gamma Correction for ProCon Interval Control.
002
Env Corr *ENG [0 to 1 / 1 / 1/step]
Sets ON/OFF for Environment Correction for ProCon Interval Control.
003
AbsHum Threshold *ENG [0.0 to 99.0 / 4.3 / 0.1g/m3/step]
Sets Absolute Humidity Threshold for Environment Correction for ProCon Interval Control.
004
Max Cnt *ENG [0 to 99 / 2 / 1time/step]
Sets Maximum Count Threshold for Interruption ProCon/Job End ProCon.
005
Exe Cnt *ENG [0 to 255 / 0 / 1time/step]
Displays Maximum Count for Interruption ProCon/Job End ProCon.
006
Page Cnt:BW *ENG [0 to 5000 / 0 / 1page/step]
Displays ProCon (BW) Page Counter.
007
Page Cnt:FC *ENG [0 to 5000 / 0 / 1page/step]
Displays ProCon (FC) Page Counter.
3530 [PowerON ProCon :Set]
001
Non-use Time Setting *ENG [0 to 1440 / 30 / 1min/step]
Sets ProCon Execution Judgment Threshold when the power is ON.
002
Temperature Range *ENG [0 to 99 / 10 / 1deg/step]
Sets ProCon Execution Judgment Threshold when the power is ON.
SP3-XXX (Process)
35