Relative Humidity Range *ENG [0 to 99 / 50 / 1%RH/step]
Sets ProCon Execution Judgment Threshold when the power is ON.
004
Absolute Humidity Range *ENG [0 to 99 / 6 / 1g/m3/step]
Sets ProCon Execution Judgment Threshold when the power is ON.
005
Interval:BW *ENG [0 to 5000 / 0 / 1page/step]
Sets ProCon Execution Judgment Threshold when the power is ON.
006
Interval:FC *ENG [0 to 5000 / 0 / 1page/step]
Sets ProCon Execution Judgment Threshold when the power is ON.
007
Page Cnt:BW *ENG [0 to 5000 / 0 / 1page/step]
Sets ProCon (BW) Page Counter when the power is ON.
008
Page Cnt:FC *ENG [0 to 5000 / 0 / 1page/step]
Sets ProCon (FC) Page Counter when the power is ON.
3532
[JobIn Procon :Set]
Sets ProCon Execution Judgment Threshold during the waiting time.
001 Non-use Time Setting *ENG [0 to 1440 / 30 / 1min/step]
002 Temperature Range *ENG [0 to 99 / 3 / 1deg/step]
003 Relative Humidity Range *ENG [0 to 99 / 10 / 1%RH/step]
004 Absolute Humidity Range *ENG [0 to 99 / 3 / 1g/m3/step]
3533 [Interrupt ProCon :Set]
001
Interval:Set:BW *ENG [0 to 5000 / 0 / 1page/step]
Sets Interruption ProCon (BW) Page Interval.
002
Interval:Disp:BW *ENG [0 to 5000 / 0 / 1page/step]
Displays Interruption ProCon (BW) Page Interval.
003
Corr(Short):BW *ENG [0.00 to 1.00 / 0.50 / 0.01/step]
Sets Correction Coefficient (Short) for Page Interval for Interruption ProCon (BW).