061
Line Width Adj.:K *ENG [-5 to 5 / 0 / 1/step]
Sets Line Width Adj. (K) [Operator Adjustment Item].
062
Line Width Adj.:C *ENG [-5 to 5 / 0 / 1/step]
Sets Line Width Adj. (C) [Operator Adjustment Item].
063
Line Width Adj.:M *ENG [-5 to 5 / 0 / 1/step]
Sets Line Width Adj. (M) [Operator Adjustment Item].
064
Line Width Adj.:Y *ENG [-5 to 5 / 0 / 1/step]
Sets Line Width Adj. (Y) [Operator Adjustment Item].
3624 [TC Adj. Mode]
001
Target(Upp Limit) *ENG
[0.00 to 1.00 / 0.15 / 0.01 mg/
cm2/-kV/step]
Sets Development gamma Adjustment Target (Upp Limit) for Toner Density Adjustment.
002
Target(Lwr Limit) *ENG
[0.00 to 1.00 / -0.10 / 0.01 mg/
cm2/-kV/step]
Sets Development gamma Adjustment Target (Lwr Limit) for Toner Density Adjustment.
3630 [Dev gamma :Disp/Set]
001
Current: K *ENG
[0.10 to 6.00 / 0.10 / 0.01 mg/
cm2/-kV/step]
Displays the latest Development gamma (K).
002
Current: C *ENG
[0.10 to 6.00 / 0.10 / 0.01 mg/
cm2/-kV/step]
Displays the latest Development gamma (C).
003
Current: M *ENG
[0.10 to 6.00 / 0.10 / 0.01 mg/
cm2/-kV/step]
Displays the latest Development gamma (M).
1. Main SP Tables-3
48