012
Threshold : Volume Count : full *ENG
[0.0 to 10000000.0 / 480000.0 /
0.1mg/step]
Value increase: Upper limit for Waste
Toner Volume from Mecha Detection
increases.
Value decrease: Upper Limit for Waste
Toner Volume from Mecha Detection
decreases.
Threshold for Full detection. Displays Waste Toner Volume Threshold for Full from Mecha
Detection.
013
Threshold : Volume Count : empty *ENG
[0.0 to 10000000.0 / 960000.0 /
0.1mg/step]
Value increase: Printed pages until when
the machine recognizes that the new
bottle is set increases.
Value decrease: Printed pages until
when the machine recognizes that the
new bottle is set decreases.
Threshold for New Part detection. Displays Waste Toner Volume Threshold from Near Full
and Full to New Part.
014
Threshold : Remainder days *ENG
[0 to 255 / 15(Office a, Office b),
29(Pro a, Pro b) / 1day/step]
Value increase: The days until when the
Near Full message is displayed after
Mecha Detection become short.
Value decrease: The days until when the
Near Full message is displayed after
Mecha Detection become long.
Displays the threshold for remainder days indicating the timing to display the Near Full
message after Mecha Detection.
021
Solid M/A *ENG
[0.00000 to 1.00000 / 0.00500 /
0.00001 mg/mm2]
Solid M/A
1. Main SP Tables-3