022
Background M/A *ENG
[0.00000 to 1.00000 / 0.00002 /
0.00001 mg/mm2]
Background M/A
023
Percentage of Transfer Ratio *ENG [0 to 100 / 81 / 1/step]
Percentage of Transfer Ratio
024
Date of detection for near full *ENG [0 to 1 / 0 / 1/step]
Displays Date of detection for near full.
3810 [Lubricant End Detection]
001
Near End Detection Distance:
Thres1:Bk
*ENG [0 to 999999999 / 0 / 1cm/step]
Distance Threshold (K) between Mecha Detection and Near End Detection (Near End
Display)
002
Near End Detection Distance:
Thres1:FC
*ENG [0 to 999999999 / 0 / 1cm/step]
Distance Threshold (FC) between Mecha Detection and Near End Detection (Near End
Display)
003
End Detection Distance: Thres2:Bk *ENG
[0 to 999999999 / 1200000 / 1cm/
step]
Distance Threshold (K) between Mecha Detection and End Detection
004
End Detection Distance: Thres2:FC *ENG
[0 to 999999999 / 1200000 / 1cm/
step]
Distance Threshold (FC) between Near End Detection and End Detection
005
Conduction Detection
Times:Thres3
*ENG [0 to 9 / 1 / 1/step]
Conduction Detection Times Threshold
Normal -> Conduction Detection Times in Mecha Detection
Shifting to Mecha Detection becomes slow if Conduction Detection Times increases.