1.SC Codes
160
Error Name/Error Condition/Major Cause/Solution
Positioning Roller Rotation Motor Error
A discharge or short circuit was detected on the motor drive board (this SC issues
immediately at first error).
Connector loose, broken, defective
Replace the Positioning Roller Rotation Motor, reconnect the connector.
Replace the harnesses.
Replace the Main Board.
Resolve the mechanical failure for the Stapler mechanism.
Error Name/Error Condition/Major Cause/Solution
Trailing Edge Press Motor Error
The stack plate drive unit in the staple unit did not return to the home position
within specified number of pulses. (The first time: jam display, the second
time: SC)
When the stack plate drive unit in the staple unit moved from the home
position, home position was still detected after specified number of pulses.
(The first time: jam display, the second time: SC)
DC motor drive software detected an error.
During the initial operation, after performing retry, the first time is jam supply
and the second time is SC.
At all times other than during initial operation, the first time is SC.
Connecter disconnected
Overload
Encoder defective
Home position sensor defective
Replace Trailing Edge Press Motor, reconnect the connector.
Replace Trailing Edge Press Plate HP Sensor, reconnect the connector.
Replace the harnesses.
Replace the Main Board.
Resolve the mechanical failure for the Stapler mechanism.
Error Name/Error Condition/Major Cause/Solution
Leading Edge Stopper Motor Error
When moving to the home position, home position was not detected within
specified number of pulses. (The first time: jam display, the second time: SC)