• [FCS]
[Heat Roller Temp: Clr/Sp], [Heat Roller Temp: White]
• [S]
[Heat Roller Temp: Clr/Sp], [Heat Roller Temp: White]
• [BW/FC/FCS: Fuser Setting HQ]
[Heat Roller Temp]
• [FCS: Fuser Setting HQ]
[Heat Roller Temp: Clr/Sp], [Heat Roller Temp: White]
• [S: Fuser Setting HQ]
[Heat Roller Temp: Clr/Sp], [Heat Roller Temp: White]
3. Select 1232: [Fusing Temperature], and then set the value in the following corresponding
settings to 0°C.
• [BW/FC/FCS]
[Corct Temp: Initial Feed]
• [FCS]
[Corct Temp: Init Fd: Clr/Sp], [Corct Temp: Init Fd: White]
• [S]
[Corct Temp: Init Fd: Clr/Sp], [Corct Temp: Init Fd: White]
• [BW/FC/FCS: Fuser Setting HQ]
[Corct Temp: Initial Feed]
• [FCS: Fuser Setting HQ]
[Corct Temp: Init Fd: Clr/Sp], [Corct Temp: Init Fd: White]
• [S: Fuser Setting HQ]
[Corct Temp: Init Fd: Clr/Sp], [Corct Temp: Init Fd: White]
4. Select 1232: [Fusing Temperature], and then set the value in the following corresponding
settings to 5°C.
• [BW/FC/FCS]
[Corct Temp: Pre-Feed]
• [FCS]
[Corct Temp: Pre-Fd: Clr/Sp], [Corct Temp: Pre-Fd: White]
• [S]
[Corct Temp: Pre-Fd: Clr/Sp], [Corct Temp: Pre-Fd: White]
• [BW/FC/FCS: Fuser Setting HQ]
[Corct Temp: Pre-Feed]
5. Image Quality Problem: Lines