Magnification Correction (2)
If a custom paper is selected with the paper library, the
magnification settings in SP2102 are not used.
The settings of SP2950 to 2953 are used instead.
The user can also adjust the magnification using Custom Paper >
Advanced Settings, as shown below.
15: Side 1 main scan
16: Side 1 sub scan
17: Side 2 main scan
18: Side 2 sub scan
Range: -0.5% to +0.5%