Troubleshooting and routine maintenance
67
B
Cleaning the corona wire B
If you have print quality problems, clean the
corona wire as follows:
a Turn off the machine’s power switch.
Disconnect all cables, and then unplug
the power cord from the electrical
socket.
b Open the front cover.
c Slowly take out the drum unit and toner
cartridge assembly.
We recommend that you place the drum
unit and toner cartridge assembly on a
clean, flat surface with a piece of
disposable paper or cloth underneath it in
case you accidentally spill or scatter toner.
Handle the toner cartridge carefully. If toner
scatters on your hands or clothes, wipe or
wash it off with cold water at once.
To prevent damage to the machine caused
by static electricity, DO NOT touch the
electrodes shown in the illustration.
d Clean the corona wire inside the drum
unit by gently sliding the blue tab from
right to left and left to right several times.
Be sure to return the blue tab to the home
position (a) (1). If you do not, printed pages
may have a vertical stripe.
e Put the drum unit and toner cartridge
assembly back in the machine.
f Close the front cover.
1