FAMILY
10
MENU
DEFAULT VALUE FACTORY
SET
MINIMUM
VALUE
MAXIMUM
VALUE
ACCESS LEVEL
NOTES
SET
VALUE
DECR COOLING SP 0°C 0°C 10°C SERVICE
PUMP DUTY CYCLE 85 0 100 INSTALLER
RESET CH TIMERS FUNCTION NOT ACTIVE FUNCTION NOT ACTIVE FUNCTION ACTIVE INSTALLER
DHW THERMOSTAT RELATED RELATED ABSOLUTE
INSTALLER: only in
instantaneous confi guration
SLIDING OUTLET
DEACTIVATE FUNCTION DEACTIVATE FUNCTION ACTIVATE FUNCTION
INSTALLER: only in “heating only”
confi g. and water tank with probe
CH DELAY POST-DHW 0 0 1 SERVICE
CH DELAY TIME 6 sec 1 sec 255 sec
SERVICE: if CH DELAY POST-
DHW = 1
PRESS TRANSDUCER 1 0 1 SERVICE
AUTO WATER FILL ENABLE 1 0 1
SERVICE: only if PRESS
TRANSDUCER = 1
BEGIN SYSTEM FILLING 0.6 0.4 1
SERVICE: only if AUTO WATER
FILL ENABLE = 1
PREHEATING 0 0 2
SERVICE: only in instant. confi g.
and managed by the control board
DHW DELAY 0 sec 0 sec 60 sec SERVICE: only in instant. confi g.
DO_AUX1 0 0 2
INSTALLER: only if control boards
with OTBus
CONFIG OTBUS 1 0 1
SERVICE: only if control boards
with OTBus
WEATHER COMPENSATION INSTALLER
CLIMATIC CURVES MAIN MAIN / ZONE 1 / ZONE 2 INSTALLER
FIXED SET POINT
80.5 °C (HT)
45 °C (LT)
MIN CH SET MAX CH SET
INSTALLER: if EXTERNAL
PROBE NOT connected
NIGHT COMP FUNCTION NOT ACTIVE FUNCTION NOT ACTIVE FUNCTION ACTIVE
INSTALLER: if EXTERNAL
PROBE connected
CURVE SLOPE
2.0 1.0 3.0
INSTALLER: if EXTERNAL
PROBE, request type TA and
zone type HT
0.4 0.2 0.8
INSTALLER: if EXTERNAL
PROBE, request type TA and
zone type LT
2.0 1.0 5.0
INSTALLER: if request type
AMBIENT PROBE or REC10CH
AMBIENT INFLUENCE
10 0 20
INSTALLER: if request type
AMBIENT PROBE or REC10CH
OFFSET
20°C 20°C 40°C
INSTALLER: if request type
AMBIENT PROBE or REC10CH
COOLING 18°C 4°C 20°C
INSTALLER: if COOLING CURVE
deactivated
COOLING CURVE
1 1 2
INSTALLER: if COOLING CURVE
activated
BUILDING TYPE 5 min 5 min 20 min
INSTALLER: if EXTERNAL
PROBE connected
OUTDOOR REACTIVITY 20 0 255
INSTALLER: if EXTERNAL
PROBE connected
ENABLE/DISABLE COOLING CURVE
INSTALLER: if HP present and
enable to COOLING
RANGE RATED not used INSTALLER
CALIBRATION INSTALLER
MIN see MULTIGAS TABLE INSTALLER
MAX see MULTIGAS TABLE INSTALLER
RLA see MULTIGAS TABLE INSTALLER
MAX CH see MULTIGAS TABLE INSTALLER
COMBUSTION ANALYSIS INSTALLER
ACTIVATE FUNCTION INSTALLER
DEACTIVATE FUNCTION INSTALLER
MAX SPEED MAX INSTALLER
RANGE RATED SPEED RANGE RATED INSTALLER
MIN SPEED MIN INSTALLER
CHANGE FAN SPEED CURRENT SPEED MIN MAX INSTALLER
ANTI-LEGIO
WEEKLY FUNCTION
FUNCTION NOT ACTIVE / DAILY FUNCTION / WEEKLY
FUNCTION
INSTALLER: only if “only heating”
confi g. and water tank with probe
ANTILEGIO FLOW 80°C 65°C 85°C INSTALLER
ANTILEGIO TIME 03:00 00:00 23:30 INSTALLER
ANTILEGIO TEMP 70°C 55°C WATER TANK T MAX INSTALLER
AIR PURGING CYCLE FUNCTION DISABLED FUNCTION DISABLED FUNCTION ENABLED SERVICE
FUNCTION DISABLED SERVICE
FUNCTION ENABLED SERVICE
STOP FUNCTION
INSTALLER: only if AIR
PURGING CYCLE in progress