2. TECHNICAL DATA
2.1 TECHNICAL DATA
Gas oil is not permitted on low level discharge of flue gas products.
2.2 OVERALL DIMENSIONS
2.3 WORKING FIELD
(as EN 267)
TYPE 489T50 488T50
Output – Thermal power
(with air at 20°C)
3.0 – 5.8 kg/h 4.7 – 9.5 kg/h
35.6 – 68.7 kW 55.7 – 113 kW
(H
i
= 11.97 kWh/kg)
Fuel
Kerosene, viscosity 1.6 – 6 mm
2
/s at 20 °C
Gas oil, viscosity 4 – 6 mm
2
/s at 20 °C
Electrical supply Single phase, ~ 50Hz 230V ± 10%
Motor Run current 1.3A 2750 rpm 288 rad/s
Capacitor 5
µ
F
Ignition transformer Secondary 8 kV 16 mA
Pump
Kerosene, maximum pressure 10 bar (145 psi)
Gas oil, maximum pressure 15 bar (218 psi)
Absorbed electrical power 0.16 kW
BurnerFlange
167 A 253
30
11
204
D1844
83 83
268
163
45°
45°
189
168
140
106
ø B
A 78 111
ø B 88 105
489T50
488T50
0.4
Pressure in the combustion
chamber – mbar
Fuel output - kg/h
Thermal power - kW
D1845
0.2
0.6
0.8
1.0
1.2
3456789
30 40 50 60 70 80 90 100 110
0
1.4
10
488 T50489 T50