Table of Contents
Table of Contents
3
Information and General Instructions
5
Information about the Instruction Manual
5
Introduction
5
General Dangers
5
Other Symbols
5
Delivery of the System and the Instruction Manual
6
Guarantee and Responsibility
6
Safety and Prevention
7
Introduction
7
Personnel Training
7
Technical Description of the Burner
8
Burner Models Designation
8
Technical Data
8
Electrical Data
9
Standard Equipment
9
Burner Dimensions
10
Firing Rates
11
Procedure to Refer Burner Operating Condition at an Altitude And/Or at a Combustion Supporter Air Temperature Different to the Standard Values (328 Ft above Sea Level, 68 °F)
12
Minimum Furnace Dimensions
12
Burner Description
13
RFGO-A13 Control Box
14
Servomotor SQM41
15
Installation
16
Notes on Safety for the Installation
16
Handling
16
Preliminary Checks
16
Preparing the Boiler
16
Boiler Plate
16
Blast Tube Length
17
Securing the Burner to the Boiler
17
Combustion Head Setting
18
Ignition Pilot Adjustment
19
Electrical Connections
20
Gas Supply
21
Gas Piping
21
Gas Train
21
Gas Pressure
22
Electrical Wiring
23
Notes on Terminals
23
Supply Cables and External Connections Passage
24
Thermal Relay Calibration
25
Electro-Mechanical Thermal Relay
25
Electronic Thermal Relay
25
Motor Connection at 208-230 or 460V
26
Motor Connection at 575V
26
Reversible Direction
26
Burner Operation
27
Burner Starting
27
Steady State Operation
27
Firing Failure
27
Burner Flame Goes out During Operation
27
Start-Up, Calibration and Operation of the Burner
28
Notes on Safety for the First Start-Up
28
Adjustments before First Firing
28
Servomotor
29
Servomotor Adjustment
30
Disengage the Gears of the Servomotor
30
Cams Adjustment
30
Servomotor Positioning
30
Burner Start-Up
30
Final Calibration of the Pressure Switches
31
Air Pressure Switch
31
Maximum Gas Pressure Switch
31
Minimum Gas Pressure Switch
32
Burner Firing
32
Burner Calibration
33
Firing Output
33
Maximum Burner Output
33
Minimum Burner Output
33
Intermediate Outputs
34
TRIM Potentiometers Functions Calibration
34
Range Adjustment Range
34
Final Checks (with the Burner Working)
35
Maintenance
36
Notes on Safety for the Maintenance
36
Maintenance Programme
36
Maintenance Frequency
36
Safety Test - with Gas Ball Valve Closed
36
Checking and Cleaning
36
Flame Presence Check
37
Safety Components
37
Opening the Burner
38
Closing the Burner
38
LED Indicator and Special Function
39
Description of LED Lamps
39
Check Mode Function
39
Flame Control Lock-Out or Emergency Stop Condition
39
LED Lamps: Burner Operating Status
40
Problems - Causes - Remedies Signalled by LED Indicators
41
A Appendix - Spare Parts
46
B Appendix - Accessories
49
Appendix - Burner Start up Report
50
Other manuals for Riello RS 190
Manual
24 pages
Need help?
Do you have a question about the Riello RS 190 and is the answer not in the manual?
Ask a question
Riello RS 190 Specifications
General
Fuel Type
Light oil
Burner Type
Monoblock
Nozzle Type
Pressure jet
Operation
Two-stage
Air Regulation
Mechanical
Control System
Electronic control box
Related product manuals
Riello RS 190/M
24 pages
Riello RS 190/E
76 pages
Riello RS 100
52 pages
Riello RS 150/M
48 pages
Riello RS 100/M
56 pages
Riello RS 100/E
76 pages
Riello RS 120/M BLU
52 pages
Riello RS 160/M BLU
52 pages
Riello RS 120/EV BLU
80 pages
Riello RS 160/EV BLU
80 pages
Riello RS 1300/EV BLU
56 pages
Riello RS 28/1
40 pages