EasyManua.ls Logo

Riello RS 300/E LN - Panel Board Description

Riello RS 300/E LN
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20008423
12
GB
Technical description of the burner
3.7.2 Panel board description
1 “OFF - LOCAL - REMOTE” switch
2 “POWER ON” signal
3 “CALL FOR HEAT” signal
4 Terminal strip “XAUX”
5 “FUEL ON” signal
6 “ALARM SILENCE” button
7 “BURNER LOCK-OUT and RESET” pushbutton
8 Low air pressure switch
9 Operator panel with LCD display
10 Burner terminal board “X1”
11 Control box for checking flame and air/fuel ratio
12 Ignition transformer “TA”
13 Control box trasformer “T1”
14 Step-down trasformer (available)
15 Terminal strip “X2”
16 Fan motor contactor and thermal relay with reset button
17 “K6” relay (only for star/delta version)
18 Bracket for shielded cables with thumbscrew
Warning: used only to avoid a break in the cable’s shielding,
hence do not overtighten.
19 “KS1” contactor (only for star/delta version)
20 Auxiliary fuse
21 DIN bar for: relay, fuse holder and terminal strip “XAUX”
22 Horn
23 ”K1” relay
24 “K3” relay
25 “K5” relay
26 “K2” relay
27 “KL1” contactor (only for star/delta version)
28 “K7” relay
29 “KT1” contactor (only for star/delta version)
30 DIN bar for “X2” terminal strip, thermal relays and contactors
31 “KST1” Star/delta starter timer (only for star/delta version)
32 Holes for cables grommets for electrical wirings, accessories
and power supply (to be carried out by the installer)
33 Plug/socket for maximum pressure switch
34 Plug/socket for air actuator
35 Plug/socket for QRI flame sensor
Two types of burner failure may occur:
Flame safeguard lock-out
If the flame safeguard alarm 6)(Fig. 6) lights up, it indicates
that the burner is in lock-out. To reset, press the reset push-
button.
Fan motor trip
release by pressing the pushbutton on thermal overload
16)(Fig. 6). See “Thermal relay calibration” on page 25.
*
DIRECT START ( RS 300/E)
11
20
9
14
7
6
5
3
2
1
32
10
16
15
18
32
30
8
24
13
12
23
21
28
25
4
22
26
*
33
34
35
START / DELTA START (RS 400-500/E)
17
31
29
19
27
Fig. 6
D11897

Table of Contents