Home
Riello
Burner
RX 300 S/PV
Riello RX 300 S/PV User Manual
56 pages
Manual
Specs
Ask a question
To Next Page
To Next Page
Loading...
20062175 (3) -
02/2015
Installation, use and mainte
nance instructions
Premixed gas burners
Progressive two-stage or
modulating operati
on
CODE
MODEL
20064445
RX 180 S/PV
20055507
RX 250 S/PV
20060003
RX 300 S/PV
20059983
RX 300-33 S/PV
GB
2
Table of Contents
Table of Contents
3
Information and General Warnings
5
Information about the Instruction Manual
5
Introduction
5
General Dangers
5
Other Symbols
5
Delivery of the System and the Instruction Manual
6
Guarantee and Responsibility
6
Owner's Responsibility
7
Safety and Prevention
8
Introduction
8
Personnel Training
8
Technical Description of the Burner
9
Technical Data
9
Electrical Data
9
Packaging - Weight - Approximate Measurements
10
Burner Dimensions
10
Burner Description
11
Burner Equipment
11
Firing Rates
12
Burner Controls (LME71
15
Indication of Diagnostics Mode
20
Installation
21
Notes on Safety for the Installation
21
Handling
21
Preliminary Checks
22
Operating Position
22
Preparing the Boiler
23
Boring the Boiler Plate
23
Head Length
23
Probe - Electrodes Positioning
24
Securing the Burner to the Boiler
25
Fuel Supply
26
Air/Gas Mixer
26
Gas Train
27
Electrical Wiring
28
Supply Cables and External Connections Passage
29
Opening Sequence of the Fuse-Holder
30
Start-Up, Calibration and Operation of the Burner
31
Notes on Safety for the First Start-Up
31
Adjustments before First Firing
31
Burner Start-Up
31
Fan Adjustment
32
Matching the Working Points "Speeds for Low-Fire (P1), Ignition Load (P0) and High-Fire (P2) for the Heating Engineer
32
To the Application
32
Burner Shut down
34
Gas Valve Adjustment
34
Burner Adjustment
34
Optimum Calibration Values
34
Check of Modulating Operation
35
Display of Preset Output
35
Load Controller Inputs
35
5.10 Factory Wiring Diagram
36
Maintenance
38
Notes on Safety for the Maintenance
38
Maintenance Programme
38
Maintenance Frequency
38
Checking and Cleaning
38
Recommended Preventive Maintenance Schedule
41
Opening and Closing the Burner
41
Operation, Indication, Diagnostics
42
Control Sequence in the Event of Fault
42
Fault Status Messages, Display of Errors
42
Display of Errors (Faults) with Lockout
42
Error Code List with Operation Via Internal LED
43
Resetting the Burner Control
44
Operation
44
Manual Adjustment
44
Diagnostics of Cause of Fault
46
First Startup with a New Program Module or in Case of Replacement of Program Module
47
Manual Restore
48
Errors During the Restore Process
49
Reset
49
A Appendix - Spare Parts
50
Appendix - Accessories
52
Appendix - Burner Start up Report
53
Need help?
Do you have a question about the Riello RX 300 S/PV and is the answer not in the manual?
Ask a question
Riello RX 300 S/PV Specifications
General
Burner Output
300 kW
Air Pressure Switch
Yes
Voltage
230V
Motor Power
0.37 kW
Fuel Type
Natural Gas
Burner Type
Monobloc
Operation
Two Stage
Control Box
Riello
Related product manuals
Riello RX 150 S/PV
56 pages
Riello RX 500 S/PV
60 pages
Riello RX 250 S/PV
68 pages
Riello RX 70 S/PV K
52 pages
Riello RLS 300/E
60 pages
Riello RS 300/E BLU
56 pages
Riello P 300 P/G
56 pages
Riello RG4S
70 pages
Riello RL 70
40 pages
Riello RS BLU
44 pages
Riello RS 100
52 pages
Riello RS 50/E
40 pages