RIGOL 
DG1000Z Quick Guide  19 
To Output Harmonics 
 
DG1000Z can be used as a harmonic generator to output harmonic with specified 
order, amplitude and phase. This section introduces how to output the 2
nd
 and 4
th
 
harmonics from the [CH1] connector (Harmonic Amplitude: 2Vpp and 1Vpp, Phase: 
30° and 50°, Order: 5). 
 
1.  To select output channel 
Press CH1|CH2 to select CH1. Now the boarder of the channel status bar is 
displayed in yellow. 
 
2.  To set the parameters of the fundamental waveform 
Set the frequency/period, amplitude/high level, offset/low level and start phase 
of the fundamental waveform according to “To Output Basic Waveform”. 
 
3.  To enable the harmonic function 
Press Sine  Harm to select “On”. Press Harmonic Para to enter the 
harmonic setting menu. 
 
4.  To set harmonic order 
Press Order in the harmonic setting menu, use the numeric keyboard to input 5 
and press Sure. 
  The range is limited by the maximum output frequency of the instrument as 
well as the fundamental waveform frequency. 
  Range: integers within 2 to maximum output frequency of the 
instrument ÷  fundamental waveform frequency. The maximum is 8. 
 
5.  To select harmonic type 
Press Type in the harmonic setting menu to select Even or User. 
Method 1: Even 
Press this key and the instrument would output fundamental waveform and 
even harmonics (the 2
nd
 and 4
th
 harmonics).   
Method 2: User 
Press this key and the instrument would output the user-defined orders of 
harmonics. The highest order is 8.   
8 bits binary data is used to represent the output status of the 8 orders of 
harmonics respectively, wherein, 1 represents enabling the output of the 
corresponding harmonic and 0 represents disabling the output of the 
corresponding harmonic. Users only need to use the numeric keyboard to 
modify the value of each data bit (note: the leftmost bit representing 
fundamental waveform is always X and cannot be modified). For example, set 
the 8 bits data to X101 0000, thus 2
nd
 and 4
th
 orders of harmonics are output. 
 
Note: the actual harmonics output is determined by  the  “Order” and “Type” 
currently specified.