Chapter 2 Command System RIGOL
DP800 Programming Guide 2-29
:MONItor:VOLTage:CONDition
Syntax :MONItor:VOLTage:CONDition {<V|>V|NONE},{AND|OR|NONE}
:MONItor:VOLTage:CONDition?
Description Set the voltage monitor condition of the monitor.
Query the voltage monitor condition of the monitor.
Parameter
Name Type Range Default
{<V|>V|NONE} Discrete <V|>V|NONE NONE
{AND|OR|NONE} Discrete AND|OR|NONE NONE
Explanation After setting the voltage monitor condition, sending
the
:MONItor:VOLTage[:VALue] <value> command can set the voltage value.
You can set the voltage monitor condition to “<Voltot “>Volt.
The actual monitor condition is the logic combination of the voltage, current
and power. You need to set the logic relation between the voltage monitor
condition and the current/power monitor conditions; you can set the logic
relation to AND, ORor None; wherein, Noneindicates that no logic
relation will be set.
Return Format The query returns condition,logic relation, for example, <V,AND.
Example :MONI:VOLT:COND <V,AND /*Set the voltage monitor condition to “<Voltand
logic relation to AND*/
:MONI:VOLT:COND? /*Query the current voltage monitor condition and
the query returns <V,AND*/
Related
Commands
:MONItor:CURRent:CONDition
:MONItor:CURRent[:VALue]
:MONItor:POWER:CONDition
:MONItor:POWER[:VALue]
:MONItor:VOLTage[:VALue]

Table of Contents

Other manuals for Rigol DP831A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DP831A and is the answer not in the manual?

Rigol DP831A Specifications

General IconGeneral
BrandRigol
ModelDP831A
CategoryPower Supply
LanguageEnglish

Related product manuals