Chapter 2 Command System RIGOL
DP800 Programming Guide 2-37
:PRESet Commands
Command List:
:PRESet[:APPLy]
:PRESet:KEY
:PRESet:USER[n]:SET:CURRent
:PRESet:USER[n]:SET:DEFault
:PRESet:USER[n]:SET:TRACk
:PRESet:USER[n]:SET:OCP
:PRESet:USER[n]:SET:OVP
:PRESet:USER[n]:SET:OTP
:PRESet:USER[n]:SET:SURE
:PRESet:USER[n]:SET:VOLTage
Note: When [n] is omitted, the operation is performed on the user-preset state currently selected by
default.
:PRESet[:APPLy]
Syntax :PRESet[:APPLy]
Description Restore the instrument to default value or user-preset value.
Explanation
Sending this command is equivalent to pressing Preset at the front panel, namely
recalling the default value or user-preset value related to the key (depend on
the
:PRESet:KEY command).
Related
Command
:PRESet:KEY