Rigol DP900 Series User Manual

Rigol DP900 Series
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Rigol DP900 Series and is the answer not in the manual?

Rigol DP900 Series Specifications

General IconGeneral
BrandRigol
ModelDP900 Series
CategoryPower Supply
LanguageEnglish

Summary

Safety Requirement

General Safety Summary

Precautions to avoid personal injury or damage to the instrument and connected products.

Safety Notices and Symbols

Explanation of WARNING, CAUTION, and DANGER notices and product safety symbols.

Measurement Category

Defines measurement categories and safety precautions for their use.

Quick Start

General Inspection

Steps for inspecting packaging, instrument, and accessories upon receipt.

Using the Protection Function

Overvoltage Protection (OVP)

Details on setting and enabling Overvoltage Protection to prevent damage.

Overcurrent Protection (OCP)

Details on setting and enabling Overcurrent Protection to limit current.

OCP Delay

Explanation of the OCP delay setting and its impact on output.

Series/Parallel Connections

Series Connections

Connecting channels in series to increase voltage capability.

Internal Series Connections

How to configure CH1 and CH2 for internal series connection.

External Series Connections

Method for connecting multiple channels externally in series.

Parallel Connections

Connecting channels in parallel to increase current capability.

Arb Function

Setting Arb Properties

Configuring repetition cycle, end state, run mode, and trigger source.

Arb Editor

Interface for creating and editing arbitrary waveforms point-by-point.

Analyzer

Common Analysis

Setting up analysis parameters for common analysis mode.

Pulse Current Analysis

Performing pulse current analysis on CH1 and CH2.

Trigger

Trigger Input

Detailed settings for trigger input, including data line and response.

Trigger Output

Detailed settings for trigger output, including control source and response.

Utility

Remote Control

User-defined Programming

Controlling the instrument using SCPI commands.

PC Software

Using RIGOL Ultra Sigma software for remote control.

Remote Control via USB

Setting up remote control communication using a USB connection.

Remote Control via LAN

Setting up remote control communication using a LAN connection.

Troubleshooting

The instrument does not start.

Troubleshooting steps for when the instrument fails to power on.

The constant voltage output is abnormal.

Steps to diagnose and resolve issues with abnormal voltage output.

The constant current output is abnormal.

Steps to diagnose and resolve issues with abnormal current output.

Specifications

DC Output (0℃~40℃)

Specifications for DC output voltage, current, and OVP/OCP ranges.

OVP/OCP Accuracy

Accuracy specifications for Overvoltage and Overcurrent Protection.