Chapter 2 Command System RIGOL
MSO7000/DS7000 Programming Guide 2-117
:POWer Commands
Command List:
:POWer:TYPE
:POWer:CURRentsource
:POWer:VOLTagesource
:POWer:QUALity:FREQREFerence
:POWer:REFLevel:METHod
:POWer:REFLevel:PERCent:HIGH
:POWer:REFLevel:PERCent:LOW
:POWer:REFLevel:PERCent:MID
:POWer:TYPE
Syntax
:POWer:TYPE <type>
:POWer:TYPE?
Description
Sets or queries the power analysis type.
Parameter
Name
Type
Range
Default
<type>
Discrete
{QUALity|RIPPle}
QUALity
Description
QUALity: By analyzing the power quality, you can test the quality of AC input lines.
RIPPle: indicates the ripple quantity of the output DC voltage.
Return
Format
The query returns QUAL or RIPP.
Example
:POWer:TYPE RIPPle /*Sets the power analysis type to RIPPle.*/
:POWer:TYPE? /*The query returns RIPP.*/
:POWer:CURRentsource
Syntax
:POWer:CURRentsource <source>
:POWer:CURRentsource?
Description
Sets or queries the current source of power quality.
Parameter
Name
Type
Range
Default
<source>
Discrete
{CHANnel1|CHANnel2|CHANnel3|CHANnel4}
CHANnel1
Return
Format
The query returns CHAN1, CHAN2, CHAN3, or CHAN4.
Example
:POWer:CURRentsource CHANnel2 /*Sets the current source to CH2.*/
:POWer:CURRentsource? /*The query returns CHAN2.*/

Table of Contents

Other manuals for Rigol DS1000U Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS1000U Series and is the answer not in the manual?

Rigol DS1000U Series Specifications

General IconGeneral
BrandRigol
ModelDS1000U Series
CategoryTest Equipment
LanguageEnglish

Related product manuals