RIGOL Chapter 2 Functions of the Front Panel of GPSA
2-74 RSA3000 User Guide
Mkr->Ref
Sets the reference level of the analyzer to the amplitude of the current marker.
⚫ If Position marker is selected, the reference level will be set to the amplitude of
the current marker.
⚫ Given a Delta marker, if the current marker is the reference marker, then the
reference level is set to the amplitude of the reference marker; if the current
marker is the Delta marker, then the reference level is set to the amplitude of the
Delta marker.
MkrΔ->CF
Sets the center frequency of the analyzer to the frequency difference between the
two Delta markers.
⚫ Only when "Delta" marker is selected, can this function be valid.
⚫ This function is invalid in zero span.
MkrΔ->Span
Sets the span of the analyzer to the frequency difference between the two Delta
markers.
⚫ Only when "Delta" marker is selected, can this function be valid.
⚫ This function is invalid in zero span.