To Suit Water Heater Models -
INFINITY 32
REU-VRM3237WG
INFINITY 26 REU- VRM2626WG
INFINITY 26i REU-VRM2632FFUG
INFINITY 20 REU-VRM2024WG
INFINITY 16 REU-VRM1620WG
INFINITY ENVIRO 32 REU-KM3237WD
INFINITY ENVIRO 26 REU-KM2635WD
B16 REU-VR1620WB
B20 REU-VR2024WB
B26 REU-VR2626WB
HD250e REU-VRM3237WC
HD200e REU-VRM2632WC
HD200i REU-VRM2632FFUC
HDC211e REU-KM3237WDC
HDC211i REU-KM3237FFUDC
Operation / Installation
Manual
Rinnai Continuous Flow Water Heaters
This appliance shall be installed in accordance with:
• Manufacturers Installation Instructions
• Current AS/NZS 3000, AS/NZS 3500 & AS/NZS 5601
• Local Regulations and Municipal Building Codes including local OH&S requirements
This appliance must be installed, maintained and removed by an Authorised Person.
For continued safety of this appliance it must be installed operated and maintained
in accordance with the manufacturers instructions.
This Appliance complies
with AS 3498:2009
SAI GLOBAL LIC. W208

Table of Contents

Other manuals for Rinnai REU-VRM2632WC

Questions and Answers

  • R
    Rhonda BruceSep 8, 2025
    What to do if Rinnai Water Heater starts then the water goes cold?
    • S
      Stacy HillSep 8, 2025
      If your Rinnai Water Heater starts but the water goes cold, verify that the power is still on and try opening your hot water tap further.
  • D
    Debra ShieldsAug 23, 2025
    What to do if my Rinnai REU-VRM2632WC has no ignition or gas supply?
    • B
      Barry MoralesAug 23, 2025
      If your Rinnai Water Heater has no ignition or gas supply, check that the gas is turned on at both the water heater and the gas meter or cylinder.
  • E
    Erin HernandezAug 25, 2025
    What to do if my Rinnai Water Heater starts then the water goes cold?
    • B
      Brian PalmerAug 25, 2025
      If your Rinnai Water Heater starts but the water goes cold, verify that the power is still on. Additionally, try opening your hot water tap further.
  • G
    gdiazAug 27, 2025
    Why does my Rinnai REU-VRM2632WC Water Heater start and then the water goes cold?
    • M
      Mark DavisAug 27, 2025
      If your Rinnai Water Heater starts and then the water goes cold, verify that the power is still on. Also, try opening your hot water tap further.
  • K
    Kristen MorganAug 27, 2025
    What to do if there is a power interruption during bath fill with my Rinnai Water Heater?
    • E
      Eric GreenAug 28, 2025
      If there's a power interruption during a bath fill and water won't flow on power reinstatement with your Rinnai Water Heater, turn off all hot water taps and press the On/Off button twice.
  • O
    Olivia MillerSep 22, 2025
    What to do if Rinnai REU-VRM2632WC water will not flow on power reinstatement?
    • E
      Eric HernandezSep 22, 2025
      If you experience a power interruption while filling a bath and the water doesn't flow when power is restored to your Rinnai Water Heater, turn off all hot water taps and press the On/Off button twice.
  • S
    smithjessicaSep 16, 2025
    How to resolve a condensate pipe blockage in my Rinnai Water Heater?
    • H
      hortegaSep 16, 2025
      To resolve a condensate pipe blockage in your Rinnai Water Heater, check for any blockages on the condensate drain path.
  • A
    Andrew LawsonSep 18, 2025
    How to check for condensate pipe blockage in Rinnai REU-VRM2632WC Water Heater?
    • P
      Paul BryanSep 18, 2025
      If you suspect a condensate pipe blockage in your Rinnai Water Heater, check the condensate drain path for any obstructions.
  • S
    Samantha FreemanSep 7, 2025
    How to fix noticeable reduction in water flow in Rinnai REU-VRM2632WC Water Heater?
    • J
      Jared PhelpsSep 7, 2025
      If you notice a reduction in water flow with your Rinnai Water Heater, the inlet water filter may need cleaning. A service call is recommended.
  • C
    carol71Sep 4, 2025
    What to do if there is power interruption during bath fill with my Rinnai REU-VRM2632WC?
    • L
      Louis PerezSep 4, 2025
      If you experience a power interruption during a bath fill and the water will not flow when the power is restored, turn off all hot water taps. Then, press the On/Off button twice.

Rinnai REU-VRM2632WC Specifications

General IconGeneral
TypeTankless
Fuel TypeGas
CondensingYes
Venting RequiredYes
Gas TypeNatural Gas
Temperature Range98°F - 140°F
CategoryResidential
Maximum BTU Input199, 000 BTU/h
Minimum BTU Input15, 000 BTU/hr
VentingPVC, CPVC
Vent LengthUp to 60 ft
Electrical Requirements120V, 60Hz
Ignition TypeElectronic
Warranty12 years heat exchanger, 5 years parts, 1 year labor