Installation and Programming Manual
3-26
ZONES: ZONE TYPE (cont’d)
Quick Key Item Default Explanation
ZONE TYPE (cont’d)
05 Instant default for
all zones
except
1 and 2
usually intended for non-entry/exit doors, window
protection, shock detection (but generally NOT for
motion detectors)
causes an immediate intrusion alarm if violated (after
the expiration of the Exit Delay)
06 I+Exit/Entry 1
(Interior+Exit/Entry 1)
---
usually assigned to motion detectors and to interior
doors protecting the area between the entry door and
the keypad
if the system is armed to the AWAY (Arm) mode: a
zone(s) so programmed will provide a delay (specified
by Exit/Entry 1) allowing entry within, and exit from, an
armed premises
if the system is armed to the STAY mode:
a zone(s) so programmed will be bypassed
2 3 xx
+
E
N
T
E
R
07 I+Exit/Entry 2
(Interior+Exit/Entry 2)
--- usually assigned to motion detectors and to interior
doors protecting the area between the entry door and
the keypad
if the system is armed to the AWAY (Arm) mode: a
zone(s) so programmed will provide a delay (specified
by Exit/Entry 1) allowing entry within, and exit from, an
armed premises
if the system is armed to the STAY mode:
a zone(s) so programmed will be bypassed
IMPORTANT NOTE:
for greater security when arming to the “STAY” mode, it
is possible for the user to eliminate the Entry Delay
period associated with any zone(s) classified as
Entry/Exit 1–by pressing the [STAY] key twice in
succession when arming the system
in effect, doing so makes it an INSTANT zone during
the “STAY” mode of operation
08 I+Exit(OP)/Entry
(Interior+Exit(OP)/Entry)
---
used for an entry/exit door that, for convenience, may
be kept open when the system is disarmed
if the system is armed to the AWAY (Arm) mode:
refer to the explanation in Zone Type 03, above
if the system is armed to the STAY mode:
the zone will be bypassed
2 3 xx
+
E
N
T
E
R
09 I+Entry Follow
Interior+Entry Follower)
--- generally used for motion detectors and/or interior
(e.g. foyer) doors which would have to be violated, after
entry, in order to disarm the system
if the system is armed to the AWAY (Arm) mode: refer
to the explanation in Zone Type 04, above
if the system is armed to the STAY mode: the zone will
be bypassed
10 I+Instant
Interior+Instant
---
usually assigned to motion detectors unaffected by user
movements during the Entry Delay period
if the system is armed to the AWAY (Arm) mode
:
a violation of this zone causes an immediate intrusion
alarm (after the expiration of the Exit Delay period)
if the system is armed to the STAY mode
:
the zone will be bypassed
11 UO Trigger --- used for a device or zone, which, if violated (at any
time) will trigger a previously-programmed Utility
Output, capable of activating an external indicator,
relay, appliance, etc.
INSTALLER PROG:
2)ZONES ↓