Installation and Programming Manual 3-25
ZONES: ZONE PARTITIONS
ZONES: ZONE TYPE
Quick Key Item Default Explanation
2 2
PARTITIONS all zones
are
assigned
to
Partition 1
programs the Partition Assignment(s) for each zone
from this display, press [ENTER]
specify its two-digit Zone Number
press [ENTER] again
the “xx” in the Z=xx designation refers the number of
the zone currently being given a partition(s) assignment
when programming a zone’s partition assignment(s),
keep in mind that in a multi-partitoned system, a zone
may be assigned to more than one partition
a system “without” partitions is regarded as having a
single partition (i.e. Partition 1)
use the [STAY] key to toggle between YES (Y) or
NO (), as to whether the currently-programmed zone is
assigned to the designated partition or use keys 1 to 8
to toggle partition status to YES (Y) or NO ()
use either the [STAT] or [BYP] keys to move the
cursor left or right, respectively
2 3
Zone
Type
ZONE TYPE ---
programs the Zone Type for each zone; there are
20 Zones Types, each defined below
to program the Zone Type for any zone:
from this display, press [ENTER]
specify its two-digit Zone Number
press [ENTER] again, and select among the following:
00 Not Used --- used to disable a zone
all unused zones should be given this designation
01 Exit/Entry 1
default for
Zone 1
used for entry/exit doors
if violated, zones given this designation will not cause
an intrusion alarm during the Entry and Exit Delay
periods specified under Exit/Entry 1 in the Time Define
section
02 Exit/Entry 2 --- as above, except that Exit/Entry 2 time intervals apply
2 3 zz
+
E
N
T
E
R
03 Exit(OP)/Entry used for an entry/exit door that, for convenience, may
be kept open during the disarmed period
such a zone behaves as described in Entry/Exit 1,
above, except that, if faulted at the time the system is
armed, it will be bypassed and NOT prevent system
arming
to avoid an intrusion alarm, however, it must be
secured before the expiration of the Exit Delay period
04 Entry Follower default for
Zone 2
usually assigned to motion detectors and to interior
doors protecting the area between the entry door and
the keypad
a zone(s) given this designation will cause an
immediate intrusion alarm when violated unless an
Entry/Exit zone was violated first
if so, an Entry Follower zone(s) will remain bypassed
until the end of the Entry Delay period
INSTALLER PROG:
2)ZONES
SUBJECT: ZONES
2)PARTITIONS ¤
P=12345678 Z=xx
Y.......
SUBJECT: ZONES
3)ZONE TYPE ¤