Installation and Programming Manual 3-59
DIALER: REPORT SPLIT (cont’d)
Quick Key Item Default Explanation
REPORT SPLIT (cont’d)
5 7 3 MS NON-URGENT ---
used to report non-urgent events
(e.g. supervisory and
test reports) to the Central Station
---
for each of the six reporting options below, use the
UP- or DOWN-arrow keys to scroll to the desired choice
and press [ENTER]
5 7 3 1
Do Not Call
do NOT report non-urgent events
to the
Central Station
5 7 3 2
Call 1
st
report non-urgent events
to the 1
st
Telephone
Number (i.e. to the corresponding Central Station
Receiver, see page 3-51)
5 7 3 3
Call 2
nd
report non-urgent events
to the 2
nd
Telephone
Number (i.e. to the corresponding Central Station
Receiver, see page 3-51)
5 7 3 4
Call 3
rd
report non-urgent events
to the 3
rd
Telephone
Number (i.e. to the corresponding Central Station
Receiver, see page 3-51)
5 7 3 5
Call All
report non-urgent events
to ALL
Telephone Numbers
(i.e. to the corresponding Central Station Receivers,
see page 3-51)
5 7 3 6
1
st
Backup 2
nd
report non-urgent events
to the 1
st
Telephone
Number (i.e. to the corresponding Central Station
Receiver, see page 3-51); if communication is
unsuccessful, call the 2
nd
Telephone Number (i.e. the
corresponding Central Station Receiver, see page 3-
51)
5 7 4 FOLLOW ME ---
specifies how calls to “Follow Me” recipients will be
placed
note that “Follow Me” (FM Enable) must first be
enabled (see page 3-54) before any calls can be
made
it is the user’s responsibility to program any “Follow
Me” Phone Numbers
such numbers are programmed by accessing the
User Functions mode (see the section on User
Functions, in the Pro-24 User’s Manual)
For each of the six reporting options below, use the
or DOWN-arrow keys to scroll to the desired choice and
Press [ENTER]
5 7 4 1
Do Not Call
Do not make any “Follow Me” calls
5 7 4 2
By Partition
Call only the “Follow Me” Phone Number specified for
the partition experiencing an alarm
5 7 4 3
Call All
In the event of an alarm on any partition, call the “Follow
Me” Phone Number(s) specified for ALL partitions
experiencing an alarm
INSTALLER PROG:
5)DAILER
↓