Installation and Programming Manual
3-60
DIALER: ALARM RESTORE
Quick Key Item Default Explanation
5 8 ALARM RESTORE
---
specifies under what conditions an
Alarm Restoral will be reported
such reporting informs the Central Station that
the specified condition(s) which occurred during
the alarm has changed
if Restoral reports are to be sent, they have to be
assigned a valid reporting code (see the
Reporting Codes section on page 3-63)
for each of the three reporting options below, use the UP-or DOWN-arrow keys to scroll to the
desired choice and press [ENTER]
5 8 1
On BTO
Not for UL Installations
Report the restoral after the audible alarm “times out”
(BTO=Bell Time Out)
5 8 2
Follow Zone
report the restoral when the zone responsible for the alarm
returns to its non-violated (secured) state
5 8 3
At Disarm
report the restoral when the system (or the partition in
which the alarm occurred) is disarmed–even if the sounder
has already “timed out”
INSTALLER PROG:
5)DAILER