Installation and Programming Manual 3-61
DIALER: PERIODIC TEST
Quick Key Item Default Explanation
5 9 PERIODIC TEST ---
for Pro-24 Test (Non-Urgent) Reports to the
designated Central Station Receiver (see page 3-51),
designate the specific time and daily interval that
such reports will take place
note that if Test Reports are to be sent, they have to
be assigned a valid reporting code (see below) which
must be recognized by the Central Station monitoring
the account(s)
set the Test Time and Daily Interval for
Test Reporting to the Central Station by following the
directions below:
use the keypad’s numeric keys (0-9) and its UP- and
DOWN-arrow keys to enter the specified time-of-day
(in 24-Hr format) when a Test Report should be sent
use the table below to specify the daily testing
intervals (D)–effective from the day of programming:
D MEANING D MEANING
0 never 4 every 4
th
day
H every hour 5 every 5
th
day
1 every day 6 every 6
th
day
2 every other day 7 once a week
3 every 3
rd
day
5 9 1 MS Test ---
the U/D Test refers to the specific time and interval
that Auto Batch downloading is scheduled
refer to the Auto Batch parameter on page 3-55 for
additional information
for detailed information, see the Pro-24
Upload/Download Software Manual)
set the time and daily interval at which the Auto Batch
mode is to occur; this is the time (and day) when the
customer’s Pro-24 will automatically call the alarm
company’s computer, effective from the day of
programming:
use the keypad’s numeric keys (0-9) and its UP- and
DOWN-arrow keys to enter the specified time-of-day
(in 24-Hr format) when an automatic download should
occur
use the table below to specify the daily downloading
intervals (D)–effective from the day of programming:
D MEANING D MEANING
0 never 4 every 4
th
day
1 every day 5 every 5
th
day
2 every other day 6 every 6
th
day
3 every 3
rd
day
7 every 7
th
day
5 9 2 UD Test ---
INSTALLER PROG:
5)DAILER
M
S TEST:
HR=00 MIN=00 D:0
UD TEST:
HR=00 MIN=00 D:0