EasyManua.ls Logo

RIX Industries MAN-2PS2B-N2 - Electrical Connections; Storage

Default Icon
57 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RIX Industries MAN-2PS2B-N2 Page 4
2.3 Electrical Connections
The motors and instrumentation are wired to a crankcase mounted control box. User to supply
power to the control box in accordance with the electrical requirements specified in Compressor
Specifications. All electrical connections should be made in compliance with local electrical codes.
2.4 Storage
If the compressor is taken out of service, provision should be made to protect against corrosion. At
a minimum gas suction and discharge lines should be capped and belt tension relieved. The
compressor should be rotated at least once every month. In corrosive environments, the unit
should be nitrogen purged.
After extended storage, or if stored without climate control, the compressor heads and valves
should be removed and inspected for corrosion. Bearings should also be inspected and/or replaced
and the relief valves should be cleaned, rebuilt, and/or replaced.