RIX Industries MAN-2PS2B-N2 Page 12
Item
Symptom
Probable Causes
Corrective Action
Mechanical failure internal
to the compressor
Inspect compressor internal
components
6
High Temperatures
Low suction pressure to
compressor
Adjust supply pressure to
range stated in Compressor
Specifications
Fans are inoperative
Repair or replace fans
High ambient temperature
Ensure ambient temperature
is within design limits
Compressor valves have
failed
Replace compressor valves
7
Loud metallic knocking
Piston is hitting valve
Measure and adjust piston
clearance
Replace back pressure
regulator
8
Ticking noise from cylinder
head
Compressor valve is worn
or broken
Replace compressor valve