24
Ethernet Mode
Disable - The option disables Ethernet operation.
Artnet - Fixture
receives Artnet protocol
gMAI
- Fixture
receives MANet I protocol
gMA2
- Fixture
receives MANet 2 protocol
sACN
- Fixture
receives sACN protocol
Ethernet To DMX - Fixture receives
protocol
from the Ethernet input and sends DMX
data to its DMX output (xture works as an "Ethernet/DMX converter",
next xture can be connected
to its DMX output and you can build a standard DMX chain by connecting another xtures.
Only one xture has to be connected to the Ethernet.
IP Address/Net Mask - Select this menu to set IP address. IP address is the Internet protocol
address.The IP uniquely identies any node (xture) on a network.
There cannot be 2 xtures with the same IP address on the network!
Default IP Address -Preset IP address, you can set up only rst byte of IP address
(2 or 10) e.g. 002.019.052.086.
Custom IP Address - The option enables to set up all bytes of IP address.
Net Mask - The option enables to set up all bytes of Net Mask.
ArtNet Universe - Use
this item to set a Universe (0-255). The Universe is a single DMX
512 frame
of 512 channels.
MANet Settings - Use this menu to set parameters for MANet operation.
MANet Universe I/II - The value of this item can be set in range 1-256.
MANet Session ID - The value of this item can be set in range 1-32.
sACN Settings - Use this menu to set parameters for sACN operation.
sACN Universe - The value of this item can be set in range 1-32000.
sACN Priority - The value of this item can be set in range 0-255.
7.2 Tab "Information"
Fixture Times - The menu provides readouts of xture and lamp operation hours.
Power On Time Hours - Select this menu to read the number of xture operation hours.
Total Hours -
The item shows the total number of the operation hours since the
Robin BMFL Blade
has been fabricated.
Resetable Hours -
The item shows the number of the operation hours that the
Robin BMFL Blade
has been powered on since the counter was last reset.
In order to reset this counter to 0, touch the text box next to the item "Resetable Hours:"
Lamp On Time Hours - Select this menu to read the number of hours of lamp operation.
Total Hours -
The item shows the total number of the lamp operation hours since the
Robin BMFL Blade
has been fabricated.
Remaining Hours -
The item shows hours remaining
to replacement of
the lamp. The initial value for this counter is 750 hours. In order to reset this counter to 0,
touch the text box next to the item "Remaining Hours:"
Lamp Strikes - Select this menu to read the number of lamp strikes.
Total Strikes - The item shows the total number of the lamp strikes since the
Robin BMFL Blade has been fabricated.
Resetable Strikes - The item shows the number of the lamp strikes since the counter was
last reset.
In order to reset this counter to 0, touch the text box next to the item "Resetable Strikes:"
Air Filters - Regular cleaning of the air lters is very important for the xture´s life and performance.
Bild-up of dust, dirt and fog uid residues reduces the xture´s light output and cooling ability.