26
July 20, 2016
Copyright © 2016 Robe Lighting - All rights reserved
All Specications subject to change without notice
10.2 Cleaning of the air ltr
Before replacing the fuse, unplug mains lead!
1. Remove the front plastic cover of the base (1) by unscrewing two fastening screws (2) on the cover.
2.
Clean the air lter (3) placed in the base. Use a vacuum cleaner, compressed air or you can wash it and
put back dry.
After replacing the air lter, reset the elapsed time counter in the menu Information.
(Info--->Air l---> R Ti.).
3. Place the base cover back and fasten it by means of two screws (2).
10.3 Disposing of the product
To preserve the environment please dispose or recycle this product at the end of its life according to the local
regulations and codes.