4. Installation
Fixtures must be installed by a qualied electrician in accordance with all
national and local electrical and construction codes and regulations.
4.1 Connection to the mains
For protection from electric shock, the xture must be earthed!
The Robin T1 Prole is equipped with auto-switching power supply that automatically adjusts to any 50-60Hz
AC power source from 100-240 Volts.
Power cable is enclosed to the xture.If you need to install a power plug on the power cable to allow connection
to power outlets, install a grounding-type (earthed) plug, following the plug manufacturer’s instructions. If you
have any doubts about proper installation, consult a qualied electrician.
Core (EU) Core (US) Connection Plug Terminal Marking
Brown Black Live L
Light blue White Neutral N
Yellow/Green Green Earth
This device falls under class one and must be earthed (grounded).
To apply power, rst check that the head pan and tilt locks are released.
4.2 Replacing the frost
Unplug the xture from mains before installing the frost module!
To replace the frost module.
1. Disconnect the xture from mains and allow it to cool for 10 minutes.
2. Remove plastic cover of the head by loosening the 2 quarter-turn fasteners on the cover to get access to
the frost module (1).
3
. The holder (2) of the frost foil is fastened to the frost holder (3) by means of the four magnets (4). Grip the
holder (2) and carefully tilt it out to break a force of magnets (4) on the frost holder (3).
4
. Place a new frost module into the frost holder (3). Check, that both slots (6) snapped correctly into two
protrusions (5) in the holder (3).
5. P
lace the plastic cover back on the xture before applying power.