TECHNICAL FILE
2500W HMI FOLLOW SPOT
message displayed :
LAMP OFF
CHECK SECURITY
Return to 1.1 and follow the
procedure.
message unchanged.
Network transient failure : give the
off command, or switch off
the mains for 30 sec.
1.2. Untimely extinction of the lamp.
2. USING THE " ANALOG " MODE
2.1. The ballast and the CAD are on ;
the" lamp on" command is given,
but the lamp does not switch on.
Check the analog command cable :
the command has not been
recieved.
( refer to Tech. File p. 14 & 24 )
message displayed :
RJ LAMP LIGHTING
TRY FAILURE
Return to 1.1 and follow the
procedure.
2.2. Intimely extinction of the lamp.
message displayed :
LAMP FAILURE
CHECK SECURITY
Command signal failure :
check the cable
( refer to Tech. File p. 14 & 24 )
Message in
start-up display :
" RJ LAMP OFF "
Restart the
"LAMP ON"
procedure.
Return to 1.1 and follow the
procedure.
message unchanged.
message unchanged.
Network transient failure : give the
off command, or switch off
the mains for 30 sec.
Restart the
"LAMP ON"
procedure.
Restart the
"LAMP ON"
procedure.
Restart the
"LAMP ON"
procedure.
1039B & 1439B