14
DOSSIER TECHNIQUE
1200W MSR/MSD COLD STRIKE FOLLOW SPOTS
DocTech1019CS_CCS_0601.ind
ADMISSIBLE LAMPS :-
PHILIPS: MSR 1200 - MSR 1200/2 - MSD 1200
OSRAM: HSR 1200 - HSR 1200/2
Manufacturer's recommendations:
• Read attentively the manufacturer's instructions.
• Positioning of the lamp and connecting of the power supply require great care. To make sure there is a good
conduction of current, the mechanical support and the electrical connections must be free form dirt and corrosion.
The clamps and brackets must be checked whenever the lighting unit has been transpoted.
• The lamp emits ultraviolet radiation. Direct exposure can be harmful to your health.
• It is recommended to avoid air draughts, also avoid exposing the lighting unit to bad weather.
• Use only when bulb in place
Technical characteristics:
User's precautions:
• The lamplife, as given by the manufacturer, is an theoretic lamplife duration as "in laboratory conditions" a cycle
based on 3 hours on / 1 hour off, cycles more brief, reduce the duration of the lamplife.
• Premature wearing of lamp under performing conditions, is mainly due to frequent switching on. Better to leave
the lamp on, through the performance, rather than switching it on repeatedly. ( The lampelife is reduced about
1 hour, each time the lamp is lighten ).
• Use over 500 hours of the lamp : change the lamp even thou it still lights up.
(For MSR 1200 - HSR 1200 and MSR 1200/2 - HSR 1200/2 lamps).
New lamp:
• To achieve a good ionization of a new lamp, when using it for the first time, it is recommended to leave it on
for a few hours.
• Preserve carefully the guarantee slip of the lamp, as it may be asked for in the event of a dispute.
Thank you.
1019 CS & CCS
1119 CS & CCS
1419 CS & CCS
Follow spot description : CS - RANGE CCS - RANGE
Voltage use : (European Standard) 230/245 Volts. 50Hz.
Voltage use : (North American standard) 208 Volts 60Hz. 110 Volts 60Hz.
Minimum voltage supply : 198 Volts 105 Volts
(Below this charge = possible ignition failure).
Lamp description : MSR 1200 MSR 1200/2 MSD 1200
HSR 1200 HSR 1200/2
Nominal adsorbed wattage : 1200 Watts 1200 Watts. 1200 Watts
Lamp voltage : 100 Volts 100 Volts 100 Volts
Lamp current : 13,8 Amps 13,8 Amps 13,8 Amps
Base : G 22 G 22 G 22
Lumen output : 110 000 L's 110 000 L's 92 000 L's
Colour temperature : 5900 Kelvin 7200 Kelvin 6000 Kelvin