Filter
Set At
14
Feature Feature Description Display Adjustment Options
Factorydefault
settings
Filter
Change
Reminder
Room
Temperature
Calibration
Minimum
Compressor
On-Time
This setting will ash FILT in the
display after the elapsed run time
to remind the user to change the
lter. The OFF setting will disable
this feature.
Next Step
Prev Step
Done
This setting allows the installer
to change the calibration of the
room temperature display so
that, for example, the thermostat
would read 72°F instead of 70°F.
Next Step
Prev Step
Done
The installer can select the
minimum run time for the
compressor to help protect the
compressor from short-cycling.
Next Step
Filter
The lter change reminder
can be adjusted from OFF
to 2000 hours in 50 hour
increments. Press the second
button from the top left side of
the thermostat to display the
current lter elapsed run time.
Set At
Min Com On
Prev Step
Done
The room temperature display
can be adjusted to read 3°
above or below the factory
calibrated temperature.
The minimum compressor run
time can be adjusted from OFF
to 3, 4, or 5 minutes. If 3, 4, or
5 is selected, the compressor
will run for at least the
selected time before turning off
(although the fan may continue
to run for a short time).
INSTALLER SETUP MENU