EasyManua.ls Logo

Robland X310 - Dust Emmission Values

Default Icon
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Accoustic
levels
-
measurements
: as per ISO
norm 7960
- as per
annexe
D
Work
station
und
load
Sawing
Moulding
Tenoning
Planing
Thicknessing
Mortising
Level
continuous
accoustic
pressure
as per
index
A
dB(A)
88
84
86
92
83
86
Level
accoust.
power
dB(A)
(MW)
103
(19,9)
97
(3,2)
97(5)
98
(6,3)
97(5)
107
(250,1)
Max.
value
accoust.
pressure
as per
index
C
(instantaneous)
dB
<130
<130
<130
<130
<130
<130
Dust
emmission
values
Type
examination
was
carried
out by the
following
approved body
:
Prufinstitut
fur
Holzstaubmessungen
Institut
fur
Werkzeugmaschinen
Universitat
Stuttgart
-
Germany
Measurements
: as per DIN 33 893
(GS-HO-05)
Measurement values show
that
the
TRK-value
of 2
mg/m3
has not
been exceeded.
Notification
number
and
date
:
08.03.1996
/
FPH-AZ
:
029/95

Related product manuals